Industry-Standard Benchmarks for Embedded Systems
EEMBC, an industry alliance, develops benchmarks to help system designers select the optimal processors and understand the performance and energy characteristics of their systems. EEMBC has benchmark suites targeting cloud and big data, mobile devices (for phones and tablets), networking, ultra-low power microcontrollers, the Internet of Things (IoT), digital media, automotive, and other application areas. EEMBC also has benchmarks for general-purpose performance analysis including CoreMark, MultiBench (multicore), and FPMark (floating-point).
» Back

ULPBench  Benchmark Scores

 Analog Devices ADuCM302x 
Hardware Environment 
Device VendorAnalog Devices
Device Name and RevisionADuCM302x Rev 1.0
Silicon RevisionRev 1.0
CoreCortex-M3
Production silicon Yes
Processor DatasheetADuCM302xDatasheet_PrF.pdf
Number of Devices in Product FamilyNot available
Board VendorAnalog Devices
Board Name and RevisionADuCM302x EZ-kit
External DC-DC (if used) 
External DC-DC datasheet (if used) 
Software Environment 
Compiler Name and VersionIAR EWARM 7.50.2.10505
Compiler Flags-Ohs --endian=little --cpu=Cortex-M3 -D __ADUCM3029__
ULPBench Profile and VersionCore Profile v.1.1
EnergyMonitor Software Version1.1.3
ULPBench Binary File 
Source Code Port Files 
Operating Conditions 
Ambient Temperature [C]25
System Supply Voltage [V]3.0
Supplemental Guide for Board Configuration & ReworkAN-1402.pdf
Board Extended Documentation 
OscillatorExternal
Profile Configuration Details 
Wakeup Timer ModuleRTC1
Wakeup Timer Clock SourceExternal Crystal
Wakeup Timer Frequency [Hz]32768
Wakeup Timer Accuracy [ppm]20
Active Power Mode NameActive
Active Mode Clock ConfigurationCPU: 26 MHz, RTC: 32 kHz
Active Mode Voltage IntegrityHigh accuracy voltage monitoring in battery and regulated supply
Inactive Power Mode NameHibernate
Inactive Clock ConfigurationCPU: OFF, RTC:32 kHz
Inactive Mode Voltage IntegrityHigh accuracy voltage monitoring in battery and regulated supply
Benchmark Scores
ULPMark™-CP 245.50 

Highlighted Fields indicate Certified Data

Disclaimer: EnergyBench score data is not intended to guide the design of power supplies